LiveView · FOR GIRA X1

Live diagnostics
for your Gira X1.

Something is not working as expected? Connect LiveView to your X1 for an initial check without importing a GPA project. Inspect real values in logic and visualisation. In the group monitor, compare current KNX and internal data-point messages with previous values and filter by source. Then check CPU, memory, services and KNX in device diagnostics. Retrieve existing logs when needed and filter by message, address or logic block. These are concrete clues for your next step; make any necessary project changes in the GPA.

For homes, businesses and professional X1 projects.

Original LiveView capture · Gira X1 hardware is required and not included
  • Get oriented quicklyCheck live values, the group monitor and X1 device status in one place without importing a project.
  • Narrow down faultsFind unanswered KNX read requests, then inspect assigned data points and where they are used.
  • Work remotelyConnect through Gira S1 and select customer systems in the device portal.

LiveView IN ACTION

LiveView in action.

72 seconds · With music

LiveView – product film

Real installation footage · Some interaction examples and S1 connections are simulated and labelled · Music: Cat Walk by Arulo (Mixkit)

Film transcript

See your X1 in a new light. Open. Connect. Check the current system state.

One alert. A clear starting point. Select the filter-change alert. See the event, acknowledgement and signal path in the logic sheet. Real system recording. The alert alone does not identify the cause.

Many sensors. One ventilation level. See room values at CO₂ Max and a ventilation-level change in the event list. Real capture of the running X1 logic.

One moment. Look again. Move through the available session recording on the timeline. Only captured data: LiveView must be running and connected during the event.

Find unanswered KNX requests. See group address, timestamp and assigned data points together. Device diagnostics beta · real log archive on request. A message does not prove the cause.

Many errors. A clearer clue. Filter logs, spot recurring entries and open the original details. Device diagnostics beta · real X1 log archive on request. No automatic root cause.

See the X1 itself. CPU, RAM, KNX and log clues: move from overview to relevant details. Device diagnostics beta · real snapshot readings; logs retrieved separately.

One point in time. More context. Switch logic sheets while keeping the selected point in the recording. Only available data from the active session. Connection gaps are not backfilled.

Your visualisation. In LiveView. Open rooms. See values, change writable points and check the feedback. Simulated example. Operate only authorised writable data points. Values are refreshed.

See every message in context. Filter KNX and internal messages. Compare current and previous values. Real X1 · individual GDS messages in the display window, not a full bus recording.

Your customer system. Within reach. Select authorised systems in the device portal and connect via Gira S1. S1, internet and permissions required. One X1 per connection. Example systems.

One condition. A clear next step. Check outside temperature, threshold and weather enable directly in the heating sheet. Real system recording. Make logic changes later in the GPA.

powered by KNETware. Independent KNETware software. Gira X1 required.

EXPLORE FEATURES

Discover the
possibilities.

Browse the features and see how they appear in the application.

View use cases

The logic timeline contains only data captured by LiveView while connected. Device logs are retrieved separately from the X1 on request and may include earlier device events.

USE CASES

LiveView
in use.

Understand your system live, test logic on the real X1 or inspect device logs when troubleshooting.

View features

GOOD TO KNOW

Requirements & questions.

Technical requirements
Computer
Windows x64 with Microsoft Edge. No GPA project import or additional X1 logic module is required.
Gira X1
Firmware 4.0 or later, valid device access and an available connection. One selected X1 per connection.
Remote access
Connect locally over the network or through a configured Gira S1 with internet access and the required device-portal permissions.
Test values
Writing to a writable data point affects the real system. Check the assignment and data type before each test.
Visualisation
Rooms, categories and functions available to your X1 account appear in the visualisation tab. Reading and writing depend on the permissions reported by the X1.
Questions about LiveView
How does LiveView help when a function is not working as expected?
Connect to the X1 and inspect current system values without importing a GPA project. Device diagnostics shows utilisation and device status; retrieve existing logs on request and filter warnings, KNX addresses or logic messages. Open the relevant visualisation function and, if appropriate, check a writable data point and its feedback. If the evidence points to a project issue, change the logic in the GPA afterwards. LiveView does not repair it automatically.
What does device diagnostics show?
A snapshot of the X1 including CPU, memory, SD card, operating status and visible services. The network view shows device information and related log clues where available. Existing X1 logs are retrieved separately on request. Filters help find KNX read requests without a timely answer, logged logic-block exceptions and data-point errors. For a KNX address, you can inspect known data points and where they are used in the X1 project. This assignment does not identify who caused a message; an entry alone does not prove the cause. Device diagnostics is currently marked beta.
What can I check in the group monitor?
The group monitor shows current messages from KNX and internal data points. Filter by “All”, “Internal” or “KNX”, and search by address or data-point name. The list shows timestamp, name, current and previous value; repeated values remain separate messages. The details for an assigned data point provide further information. At an authorised writable point, check its assignment and data type before deliberately sending a value, then watch for new messages. This is not a complete retrospective record of all KNX telegrams.
What does the visualisation tab show?
It shows the existing X1 visualisation functions by room or category, including their data points and values. Writable data points can be operated directly. LiveView uses the X1 function structure already in place. Visualisation values are refreshed periodically; they are not a complete event history.
Can I use LiveView for logic development and debugging?
Yes. The GPA simulation works with your project. LiveView connects to the running X1 and displays its real values and responses without importing the GPA project. Change the logic in the GPA when needed, transfer it to the X1 and inspect inputs, enable conditions and outputs on the real system. Signal paths, events and the available session recording help narrow down unexpected responses. LiveView is not a source-code debugger: it does not edit logic or set breakpoints. Project changes still take place in the GPA.
Can I inspect a fault from yesterday?
The logic timeline only shows the available recording from a connected LiveView session. Separately, you can retrieve available X1 device logs on request; they may contain older events. Neither view is a complete system history.
What is the difference between Single and Pro?
Single is intended for one X1. Pro lets you connect to an unlimited number of X1 systems one after another, including permitted systems in the Gira device portal. Each connection observes one selected X1; there is no simultaneous fleet monitoring.
Is LiveView suitable for my own system?
Yes. Homeowners can follow real system states live, operators can inspect current processes and professionals can test their logic on the actual X1. A basic understanding of X1 logic helps interpret the values. LiveView provides observations, not automatic root-cause detection.
Which functions can I inspect?
For example lighting, shading, heating, climate control, ventilation, audio or camera-related status signals, provided the relevant values are observable in your X1 logic. Camera images are not analysed. Input, output, logic and bus tags help identify where events came from; bus events are not a complete physical KNX bus capture.
Download brochures & presentations
Take it with you

Brochures & presentations.

ORDER

Understand your installation better.

Price, availability and delivery time are shown when ordering. Personal download link after payment.

LiveView SingleOne Gira X1. Live diagnostics locally and via Gira S1.
Go to order
LiveView ProUnlimited Gira X1 installations. One X1 per connection. Locally and via Gira S1.
Go to order